Table 4.

Reliability, feasibility, and sensitivity to change.

ReferenceInterobserverDiscrimination IntraobserverBetween-group DifferencesSensitivity to ChangeFeasibility
Gutierrez14κ of comprehensive US semiquantitative assessment at parasternal, mid-clavicular, anterior axillary, mid-axillary, paravertebral, subscapular and posterior axillary level: 0.943, 0.846, 0.963, 0.932, 0.958, 0.969, and 0.980, respectively2nd parasternal κ = 0.864, 4th mid-clavicular κ = 0.881, 4th anterior axillary κ = 0.868, 4th mid-axillary κ = 0.845, 8th paravertebral κ = 0.894, 8th subscapular κ = 0.883, 8th posterior axillary κ = 0.862NRNREstimated by comparing time spent regarding comprehensive assessment by independent samples t test. Significant difference found between comprehensive US B-lines assessment (mean 23.3 ± SD 4.5, range 16–31 min) and simplified US B-lines assessment (mean 8.6 ± SD 1.4, range 6–12 min, p < 0.00001).
Aghdashi19NRNRNRNRNR
Barskova20NRNRNRNRTime needed for the scan and analysis always < 10 min
Buda21NRNRNRNRNR
Gargani11NRNRNRNRNR
Gigante22NRNRNRNRNR
Moazedi-Fuerst23NRNRNRNRNR
Pinal-Fernandez24NRNRNRNRNR
Sperandeo12NRNRNRNRNR
Tardella13Parasternal κ = 0.943, mid-clavicular κ = 0.846, anterior-axillary κ = 0.963, medial-axillary κ = 0.932, paravertebral κ = 0.958, subscapular κ = 0.969, posterior-axillary κ = 0.980NRNRNRNR
Moazedi-Fuerst10NRNRNRNRNR
Mohammadi25Global κ value of agreement between 2 imaging methods 0.553 (p < 0.001).Global κ values for intraobserver reliability of B-lines assessment 0.838NoNRNR
  • US: ultrasound; NR: not registered.