Table 3.

Percentage of exact agreement (PEA) and close agreement (PCA) for JSN assessment in each individual joint space.

Intrareader BaselineIntrareader ChangeInterreader BaselineInterreader Change
Mean PEAMean PCAMean PEAMean PCAPEAPCAPEAPCA
CMC173.8100.087.5100.05.075.045.0100.0
CMC277.5100.092.598.80.040.055.0100.0
CMC366.395.088.8100.00.060.050.085.0
CMC452.596.376.396.30.075.055.095.0
CMC561.3100.093.8100.05.070.055.0100.0
TRM-TRD92.597.597.5100.065.0100.090.0100.0
TRD-CAP58.891.370.098.815.050.035.095.0
CAP-HAM60.898.787.398.70.050.060.095.0
TRM-SCA73.8100.081.3100.015.060.030.070.0
TRD-SCA70.095.084.8100.00.045.035.090.0
CAP-SCA78.8100.090.0100.010.085.055.085.0
CAP-LUN80.0100.091.397.55.080.060.095.0
HAM-TRI79.7100.087.3100.020.085.060.090.0
SCA-LUN82.5100.090.097.545.095.045.0100.0
LUN-TRI73.8100.083.8100.015.075.040.075.0
RAD-SCA77.5100.087.598.815.085.045.0100.0
RAD-LUN82.5100.085.0100.030.090.060.095.0
All joints (mean)74.196.086.799.214.471.851.592.4
  • Intrareader percentage of exact agreement (PEA) expresses the percentage of the patients receiving the same score twice by a single reader, and intrareader percentage of close agreement (PCA) is the percentage of the patients where the 2 readings differ no more than 1.0 in score. Intrareader PEA and PCA are presented as the mean of the 4 readers. Interreader PEA expresses the percentage of the patients receiving the same score by all 4 readers, and the interreader PCA is the percentage of the patients where the difference between the minimum and maximum score is ≤ 1.0. CMC: carpometacarpal; TRM: trapezium; TRD: trapezoid; CAP: capitate; HAM: hamate; SCA: scaphoid; LUN: lunate; TRI: triquetrum; RAD: radius.