Table 2.

Intraobserver and interobserver reproducibility of synovitis detection by 7 sonographers using OMERACT criteria and B-mode or power Doppler imaging. Synovitis was defined as at least OMERACT grade 1 (ALG1) or OMERACT grade 2 (ALG2).

ReproducibilitySonographerB-mode ALG1B-mode ALG2Power Doppler ALG1Power Doppler ALG2
Intraobserver10.750.700.480.25
20.540.610.500.35
30.530.700.640.44
40.370.630.520.77
50.410.590.520.50
60.670.620.470.44
70.670.630.660.63
Interobserver*2/ref0.460.611/ref0.370.24
3/ref0.570.682/ref0.260.60
4/ref0.450.663/ref0.550.48
5/ref0.430.555/ref0.470.44
6/ref0.520.586/ref0.390.39
7/ref0.620.657/ref0.490.48
  • * Interobserver reproducibility was assessed using the sonographer who had the best intraobserver reproducibility as the reference. This was sonographer #1 for B-mode imaging and sonographer #4 for power Doppler imaging. OMERACT: Outcome Measures in Rheumatology Clinical Trials.