Table 1.

Diagnostic properties of anti-MCV, anti-CCP2, and RF assays using optimal cutoff values.

AssaySensitivity, %Specificity, %PPV, %NPV, %AUC95% CIp
Anti-MCV78.293.493.777.40.930.89–0.95< 0.05
Anti-CCP261.896.395.566.80.850.80–0.89< 0.05
RF72.480.182.069.90.740.68–0.80< 0.05
  • CI: confidence interval; MCV: mutated citrullinated vimentin; CCP: cylic citrullinated peptide; RF: rheumatoid factor; PPV/NPV: positive/negative predictive value; AUC: area under the curve.