Skip to main content

Main menu

  • Home
  • Content
    • First Release
    • Current
    • Archives
    • Collections
    • Audiovisual Rheum
    • COVID-19 and Rheumatology
  • Resources
    • Guide for Authors
    • Submit Manuscript
    • Payment
    • Reviewers
    • Advertisers
    • Classified Ads
    • Reprints and Translations
    • Permissions
    • Meetings
    • FAQ
    • Policies
  • Subscribers
    • Subscription Information
    • Purchase Subscription
    • Your Account
    • Terms and Conditions
  • About Us
    • About Us
    • Editorial Board
    • Letter from the Editor
    • Duncan A. Gordon Award
    • Privacy/GDPR Policy
    • Accessibility
  • Contact Us
  • JRheum Supplements
  • Services

User menu

  • My Cart
  • Log In

Search

  • Advanced search
The Journal of Rheumatology
  • JRheum Supplements
  • Services
  • My Cart
  • Log In
The Journal of Rheumatology

Advanced Search

  • Home
  • Content
    • First Release
    • Current
    • Archives
    • Collections
    • Audiovisual Rheum
    • COVID-19 and Rheumatology
  • Resources
    • Guide for Authors
    • Submit Manuscript
    • Payment
    • Reviewers
    • Advertisers
    • Classified Ads
    • Reprints and Translations
    • Permissions
    • Meetings
    • FAQ
    • Policies
  • Subscribers
    • Subscription Information
    • Purchase Subscription
    • Your Account
    • Terms and Conditions
  • About Us
    • About Us
    • Editorial Board
    • Letter from the Editor
    • Duncan A. Gordon Award
    • Privacy/GDPR Policy
    • Accessibility
  • Contact Us
  • Follow jrheum on Twitter
  • Visit jrheum on Facebook
  • Follow jrheum on LinkedIn
  • Follow jrheum on YouTube
  • Follow jrheum on Instagram
  • Follow jrheum on RSS
Abstract

Diagnostic accuracy study of urine dipstick in relation to 24-hour measurement as a screening tool for proteinuria in lupus nephritis.

Mark J Siedner, Allan C Gelber, Brad H Rovin, Alison M McKinley, Lisa Christopher-Stine, Brad Astor, Michelle Petri and Derek M Fine
The Journal of Rheumatology January 2008, 35 (1) 84-90;
Mark J Siedner
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Allan C Gelber
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Brad H Rovin
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Alison M McKinley
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Lisa Christopher-Stine
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Brad Astor
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Michelle Petri
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Derek M Fine
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • Article
  • Info & Metrics
  • References
  • PDF
  • eLetters
PreviousNext
Loading

Abstract

OBJECTIVE: Early detection of renal involvement in lupus prevents poor outcomes. Although published guidelines recommend urine dipstick as an appropriate screening test and evidence suggests a majority of American rheumatologists use dipstick to screen for proteinuria, the performance of this diagnostic approach in lupus has not been reported. We examined the validity of qualitative urine dipstick versus quantitative 24-hour measurement to accurately detect proteinuria, including low-level proteinuria. METHODS: We performed a diagnostic accuracy study using paired samples from the Johns Hopkins University School of Medicine and the Ohio State University School of Medicine lupus cohorts. All qualitative urine dipstick values were obtained within 1 day of a 24-hour urine collection. RESULTS: We analyzed the performance of 3 urine dipstick assays to detect proteinuria compared to 24-hour protein/creatinine ratios, using 2224 dipstick measures from 296 patients. The sensitivity of a > or = 1+ dipstick result to detect quantitative proteinuria (> or = 0.50 g protein/g creatinine) was 82.7% for the Clinitek, 97.7% for the Atlas, and 85.5% for the Bayer assay. The corresponding sensitivity to detect low-level proteinuria, (0.50-0.99 g protein/g creatinine) was 63.1%, 96.4%, and 80.7%, respectively. The specificity to correctly exclude proteinuria (< 0.50 g protein/g creatinine) with negative/trace results was 86.1%, 62.2%, and 59.4%. There was considerable variability in the range of protein/creatinine ratios detected at each dipstick level of proteinuria. CONCLUSION: Urine dipsticks demonstrate substantial variability and often poor validity to accurately detect proteinuria at quantitative levels; this warrants further diagnostic evaluation. Clinicians should consider quantified proteinuria assays as a more accurate screening tool in the diagnostic evaluation of lupus nephritis.

PreviousNext
Back to top

In this issue

The Journal of Rheumatology
Vol. 35, Issue 1
1 Jan 2008
  • Table of Contents
  • Index by Author
Download PDF
Article Alerts
Sign In to Email Alerts with your Email Address
Email Article

Thank you for your interest in spreading the word about The Journal of Rheumatology.

NOTE: We only request your email address so that the person you are recommending the page to knows that you wanted them to see it, and that it is not junk mail. We do not capture any email address.

Enter multiple addresses on separate lines or separate them with commas.
Diagnostic accuracy study of urine dipstick in relation to 24-hour measurement as a screening tool for proteinuria in lupus nephritis.
(Your Name) has forwarded a page to you from The Journal of Rheumatology
(Your Name) thought you would like to see this page from the The Journal of Rheumatology web site.
CAPTCHA
This question is for testing whether or not you are a human visitor and to prevent automated spam submissions.
Citation Tools
Diagnostic accuracy study of urine dipstick in relation to 24-hour measurement as a screening tool for proteinuria in lupus nephritis.
Mark J Siedner, Allan C Gelber, Brad H Rovin, Alison M McKinley, Lisa Christopher-Stine, Brad Astor, Michelle Petri, Derek M Fine
The Journal of Rheumatology Jan 2008, 35 (1) 84-90;

Citation Manager Formats

  • BibTeX
  • Bookends
  • EasyBib
  • EndNote (tagged)
  • EndNote 8 (xml)
  • Medlars
  • Mendeley
  • Papers
  • RefWorks Tagged
  • Ref Manager
  • RIS
  • Zotero

 Request Permissions

Share
Diagnostic accuracy study of urine dipstick in relation to 24-hour measurement as a screening tool for proteinuria in lupus nephritis.
Mark J Siedner, Allan C Gelber, Brad H Rovin, Alison M McKinley, Lisa Christopher-Stine, Brad Astor, Michelle Petri, Derek M Fine
The Journal of Rheumatology Jan 2008, 35 (1) 84-90;
del.icio.us logo Digg logo Reddit logo Twitter logo CiteULike logo Facebook logo Google logo Mendeley logo
  • Tweet Widget
  • Facebook Like
  • Google Plus One
Bookmark this article

Jump to section

  • Article
  • Info & Metrics
  • References
  • PDF
  • eLetters

Related Articles

Cited By...

Similar Articles

Content

  • First Release
  • Current
  • Archives
  • Collections
  • Audiovisual Rheum
  • COVID-19 and Rheumatology

Resources

  • Guide for Authors
  • Submit Manuscript
  • Author Payment
  • Reviewers
  • Advertisers
  • Classified Ads
  • Reprints and Translations
  • Permissions
  • Meetings
  • FAQ
  • Policies

Subscribers

  • Subscription Information
  • Purchase Subscription
  • Your Account
  • Terms and Conditions

More

  • About Us
  • Contact Us
  • My Alerts
  • My Folders
  • Privacy/GDPR Policy
  • RSS Feeds
The Journal of Rheumatology
The content of this site is intended for health care professionals.
Copyright © 2022 by The Journal of Rheumatology Publishing Co. Ltd.
Print ISSN: 0315-162X; Online ISSN: 1499-2752
Powered by HighWire