Skip to main content

Main menu

  • Home
  • Content
    • First Release
    • Current
    • Archives
    • Collections
    • Audiovisual Rheum
    • COVID-19 and Rheumatology
  • Resources
    • Guide for Authors
    • Submit Manuscript
    • Payment
    • Reviewers
    • Advertisers
    • Classified Ads
    • Reprints and Translations
    • Permissions
    • Meetings
    • FAQ
    • Policies
  • Subscribers
    • Subscription Information
    • Purchase Subscription
    • Your Account
    • Terms and Conditions
  • About Us
    • About Us
    • Editorial Board
    • Letter from the Editor
    • Duncan A. Gordon Award
    • Privacy/GDPR Policy
    • Accessibility
  • Contact Us
  • JRheum Supplements
  • Services

User menu

  • My Cart
  • Log In
  • Log Out

Search

  • Advanced search
The Journal of Rheumatology
  • JRheum Supplements
  • Services
  • My Cart
  • Log In
  • Log Out
The Journal of Rheumatology

Advanced Search

  • Home
  • Content
    • First Release
    • Current
    • Archives
    • Collections
    • Audiovisual Rheum
    • COVID-19 and Rheumatology
  • Resources
    • Guide for Authors
    • Submit Manuscript
    • Payment
    • Reviewers
    • Advertisers
    • Classified Ads
    • Reprints and Translations
    • Permissions
    • Meetings
    • FAQ
    • Policies
  • Subscribers
    • Subscription Information
    • Purchase Subscription
    • Your Account
    • Terms and Conditions
  • About Us
    • About Us
    • Editorial Board
    • Letter from the Editor
    • Duncan A. Gordon Award
    • Privacy/GDPR Policy
    • Accessibility
  • Contact Us
  • Follow jrheum on Twitter
  • Visit jrheum on Facebook
  • Follow jrheum on LinkedIn
  • Follow jrheum on YouTube
  • Follow jrheum on Instagram
  • Follow jrheum on RSS
Abstract

OMERACT Rheumatoid Arthritis Magnetic Resonance Imaging Studies. Exercise 5: an international multicenter reliability study using computerized MRI erosion volume measurements.

Paul Bird, Bo Ejbjerg, Fiona McQueen, Mikkel Ostergaard, Marissa Lassere and John Edmonds
The Journal of Rheumatology June 2003, 30 (6) 1380-1384;
Paul Bird
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Bo Ejbjerg
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Fiona McQueen
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Mikkel Ostergaard
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Marissa Lassere
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
John Edmonds
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • Article
  • References
  • Info & Metrics
  • PDF
  • eLetters
PreviousNext
Loading

Abstract

Scoring erosions on magnetic resonance imaging (MRI) is one method of estimating damage in patients with rheumatoid arthritis (RA), but it has limitations. The aim of this pilot study was to assess the feasibility and inter-reader reliability of computer assisted erosion volume estimation in patients with RA. Intra-reader and inter-occasion reliability was also assessed, and different slice thicknesses were compared in terms of erosion volume estimation. A 3 mm slice thickness 3D gradient-echo sequence followed by a 1 mm sequence was performed at baseline and repeated within 24 h with metacarpophalangeal (MCP) joints 2 to 5 of the dominant hand included in the field of view. Three readers were instructed to grade MCP 2 and 3 using the OMERACT grading system and then to measure the erosion volume of the same joints using OSIRIS software. The inter-reader reliability of the grading method and the volume method was calculated, as well as the inter-occasion reliability, by comparing results from each reader from baseline to the followup scan. One reader performed repeat volume measurements on 5 patients to assess the intra-reader reliability. Five patients were included in the study. Expressed in terms of intraclass correlation coefficients (ICC), the inter-reader and inter-occasion reliability of the volume method were comparable to the existing OMERACT scoring system, but large systematic differences in volume estimations were found between readers. The intra-reader reliability was excellent. Good correlation was demonstrated between the total erosion scores and the total erosion volumes. For both erosion volumes and erosion scores, 1 mm and 3 mm acquisitions produced variable results between readers, with no clear pattern of underestimation or overestimation for either slice thickness. The volume estimation method was more time consuming, taking roughly 5 times as long as the scoring method. Computerized MRI erosion volume measurements are feasible, with high intra-observer and inter-occasion reliabilities. Despite high ICC, the inter-observer reliability is not sufficient for multicenter use without prior reader training and calibration. The optimal slice thickness was not determined.

PreviousNext
Back to top

In this issue

The Journal of Rheumatology
Vol. 30, Issue 6
1 Jun 2003
  • Table of Contents
  • Table of Contents (PDF)
  • Index by Author
Download PDF
Article Alerts
Sign In to Email Alerts with your Email Address
Email Article

Thank you for your interest in spreading the word about The Journal of Rheumatology.

NOTE: We only request your email address so that the person you are recommending the page to knows that you wanted them to see it, and that it is not junk mail. We do not capture any email address.

Enter multiple addresses on separate lines or separate them with commas.
OMERACT Rheumatoid Arthritis Magnetic Resonance Imaging Studies. Exercise 5: an international multicenter reliability study using computerized MRI erosion volume measurements.
(Your Name) has forwarded a page to you from The Journal of Rheumatology
(Your Name) thought you would like to see this page from the The Journal of Rheumatology web site.
CAPTCHA
This question is for testing whether or not you are a human visitor and to prevent automated spam submissions.
Citation Tools
OMERACT Rheumatoid Arthritis Magnetic Resonance Imaging Studies. Exercise 5: an international multicenter reliability study using computerized MRI erosion volume measurements.
Paul Bird, Bo Ejbjerg, Fiona McQueen, Mikkel Ostergaard, Marissa Lassere, John Edmonds
The Journal of Rheumatology Jun 2003, 30 (6) 1380-1384;

Citation Manager Formats

  • BibTeX
  • Bookends
  • EasyBib
  • EndNote (tagged)
  • EndNote 8 (xml)
  • Medlars
  • Mendeley
  • Papers
  • RefWorks Tagged
  • Ref Manager
  • RIS
  • Zotero

 Request Permissions

Share
OMERACT Rheumatoid Arthritis Magnetic Resonance Imaging Studies. Exercise 5: an international multicenter reliability study using computerized MRI erosion volume measurements.
Paul Bird, Bo Ejbjerg, Fiona McQueen, Mikkel Ostergaard, Marissa Lassere, John Edmonds
The Journal of Rheumatology Jun 2003, 30 (6) 1380-1384;
del.icio.us logo Digg logo Reddit logo Twitter logo CiteULike logo Facebook logo Google logo Mendeley logo
  • Tweet Widget
  • Facebook Like
  • Google Plus One
Bookmark this article

Jump to section

  • Article
  • References
  • Info & Metrics
  • PDF
  • eLetters

Related Articles

Cited By...

Similar Articles

Content

  • First Release
  • Current
  • Archives
  • Collections
  • Audiovisual Rheum
  • COVID-19 and Rheumatology

Resources

  • Guide for Authors
  • Submit Manuscript
  • Author Payment
  • Reviewers
  • Advertisers
  • Classified Ads
  • Reprints and Translations
  • Permissions
  • Meetings
  • FAQ
  • Policies

Subscribers

  • Subscription Information
  • Purchase Subscription
  • Your Account
  • Terms and Conditions

More

  • About Us
  • Contact Us
  • My Alerts
  • My Folders
  • Privacy/GDPR Policy
  • RSS Feeds
The Journal of Rheumatology
The content of this site is intended for health care professionals.
Copyright © 2022 by The Journal of Rheumatology Publishing Co. Ltd.
Print ISSN: 0315-162X; Online ISSN: 1499-2752
Powered by HighWire