Principles of management and results of treating the fractured femur during and after total hip arthroplasty.

NV Greidanus, PA Mitchell, BA Masri… - Instructional course …, 2003 - europepmc.org
The management of fractures of the femur during and after total hip arthroplasty can be
difficult, and treatment can be fraught with complications. The ideal scenario would be one in …

Minimum 10-year-results of extensively porous-coated stems in revision hip arthroplasty.

WG Paprosky, NV Greidanus… - Clinical Orthopaedics and …, 1999 - journals.lww.com
Obtaining predictable, stable fixation of revision femoral implants is important for the long-term
success of revision hip arthroplasty. The authors report on minimum 10 years clinical and …

Use of erythrocyte sedimentation rate and C-reactive protein level to diagnose infection before revision total knee arthroplasty: a prospective evaluation

NV Greidanus, BA Masri, DS Garbuz, SD Wilson… - JBJS, 2007 - journals.lww.com
Background: Despite the widespread use of several diagnostic tests, there is still no perfect
test for the diagnosis of infection at the site of a total knee arthroplasty. The purpose of this …

The John Charnley Award: Metal-on-metal hip resurfacing versus large-diameter head metal-on-metal total hip arthroplasty: a randomized clinical trial

DS Garbuz, M Tanzer, NV Greidanus, BA Masri… - … and Related Research®, 2010 - Springer
Resurfacing arthroplasty has become an attractive option for young patients who want to
maintain a high activity level. One recent study reported modestly increased activity levels for …

Cementless two-stage exchange arthroplasty for infection after total hip arthroplasty

BA Masri, KP Panagiotopoulos, NV Greidanus… - The Journal of …, 2007 - Elsevier
We retrospectively reviewed all patients at one center with an infected total hip arthroplasty
treated with 2-stage revision using cementless components for the second stage and the …

Prevalence of pseudotumor in asymptomatic patients after metal-on-metal hip arthroplasty

DH Williams, NV Greidanus, BA Masri, CP Duncan… - JBJS, 2011 - journals.lww.com
Background: The cause of recently reported pseudotumor formation in patients with metal-on-metal
hip replacements is unknown. It has been postulated that there is an association …

The Frank Stinchfield Award: dislocation in revision THA: do large heads (36 and 40 mm) result in reduced dislocation rates in a randomized clinical trial?

…, BA Masri, CP Duncan, NV Greidanus… - … and Related Research®, 2012 - Springer
Background Dislocation after revision THA is a common complication. Large heads have the
potential to decrease dislocation rate, but it is unclear whether they do so in revision THA. …

Intraoperative fracture of the femur in revision total hip arthroplasty with a diaphyseal fitting stem

RMD Meek, DS Garbuz, BA Masri, NV Greidanus… - JBJS, 2004 - journals.lww.com
Background: In revision total hip arthroplasty, intraoperative split fractures and cortical perforation
fractures are becoming a more common concern with the increasing use of diaphyseal …

Adverse local tissue reactions in metal-on-polyethylene total hip arthroplasty due to trunnion corrosion: the risk of misdiagnosis

…, S Zachara, TO Nielsen, NV Greidanus… - The bone & joint …, 2015 - boneandjoint.org.uk
Adverse reaction to wear and corrosion debris is a cause for concern in total hip arthroplasty
(THA). Modular junctions are a potential source of such wear products and are associated …

Durable infection control and function with the PROSTALAC spacer in two-stage revision for infected knee arthroplasty

…, BA Masri, CP Duncan, NV Greidanus… - Clinical Orthopaedics …, 2011 - journals.lww.com
Background A two-stage revision total knee arthroplasty is recognized as the gold standard
in the treatment of infection. However, traditional spacers limit function in the interval …