Skip to main content
Log in

Enzyme-linked immunosorbent assay (ELISA) screening test for detection of rheumatoid factor

  • Originals
  • Published:
Rheumatology International Aims and scope Submit manuscript

Summary

A new enzyme-linked immunosorbent assay (ELISA) screening test for total rheumatoid factor (RF) activity is described. Rabbit IgG was used as antigen and enzyme-conjugated monoclonal anti-kappa antibody as third layer. Of 183 samples measured for RF isotype levels, 60 were found to have one or more raised. In terms of raised isotypes the ELISA screening test had a sensitivity of 97% (58/60) while the Rheumaton had a sensitivity of only 75% (45/60). Nearly all discordant false-negative samples had only one RF isotype raised. The ELISA test gave 29% (53/183) and the Rheumaton 34% (63/183) false-positive results. Thus the ELISA test was more specific and sensitive for the detection of raised single RF isotypes than the Rheumaton and Rose-Waaler tests. Moreover, approximately 30% of RA patients were seronegative according to the conventional RF tests but only 8% in the new ELISA system.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. Teitsson I, Withrington RH, Seifert MH, Valdimarrson H (1984) Prospective study of early rheumatoid arthritis. I. Prognostic value of IgA rheumatoid factor. Ann Rheum Dis 43:673–678

    Google Scholar 

  2. Hay FC, Nineham LJ, Roitt IM (1975) Routine assay for detection of IgG and IgM antiglobulins in seronegative and seropositive rheumatoid arthritis. Br Med J [Clin Res] 3:203–204

    Google Scholar 

  3. Nineham LJ, Hay FC, Roitt IM (1976) Laboratory diagnosis of rheumatoid arthritis: a solid phase radioassay for IgG and IgM antiglobulins. J Clin Pathol 29:1121–1126

    Google Scholar 

  4. Carson DA, Lawrence S, Catalano MA, Vaughan JH, Abraham G (1977) Radioimmunoassay of IgG and IgM rheumatoid factors reacting with human IgG. J Immunol 119:295–300

    Google Scholar 

  5. Koopman WJ, Schrohenloher RE (1980) A sensitive radio-immunoassay for quantitation of IgM rheumatoid factor. Arthritis Rheum 23:302–308

    Google Scholar 

  6. Willems FTC, de Kort CCMK (1978) ELISA for rheumatoid factor. Lancet I:994–995

    Google Scholar 

  7. Halbert SP, Karsh J, Anken M (1980) A quantitative enzyme immunoassay for IgM rheumatoid factor using human immunoglobulin G as substrate. Am J Clin Pathol 74:776–784

    Google Scholar 

  8. Tarkowski A, Bjursten LM, Nilsson L-Å, Nygren H (1983) False positive results in class-specific rheumatoid factor (RF) assays due to interaction between RF and Fc fragments of anti-immunoglobulin indicator reagents. J Immunol Methods 58:171–182

    Google Scholar 

  9. Teitsson I, Valdimarsson H (1984) Use of monoclonal antibodies and F(ab')2 enzyme conjugates in ELISA for IgM, IgA and IgG rheumatoid factors. Immunol Methdos 71:149–161

    Google Scholar 

  10. Bampton JLM, Cawston TE, Kyle MV, Hazleman BL (1985) Measurement of rheumatoid factors by an enzyme-linked immunosorbent assay (ELISA) and comparison with other methods. Ann Rheum Dis 44:13–19

    Google Scholar 

  11. Carson DA, Lawrence S (1978) Light chain heterogeneity of 19S and 7S anti-γ-globulins in rheumatoid arthritis and subacute bacterial endocarditis. Arthritis Rheum 21:438–440

    Google Scholar 

  12. Roberts-Thomson PJ, Wernick RM, Ziff M (1982) Quantitation of rheumatoid factor by laser nephelometry. Rheumatol Int 2:17–20

    Google Scholar 

  13. Maiolini R, Ferrua B, Quaranta JF, Pinoteau A, Euller L, Ziegler G, Masseyeff R (1978) A sandwhich method of enzyme-immunoassay. II. Quantification of rheumatoid factor. J Immunol Methods 20:25–34

    Google Scholar 

  14. Hällgren R, Wide L (1977) Precipitation of 125I-labelled IgG aggregates by factors in sera of healthy individuals and of patients with rheumatoid arthritis. Ann Rheum Dis 36:21–29

    Google Scholar 

  15. Yamagata J, Barnett EV, Knutson DW, Nasu H, Chia D (1979) Characterisation and measurement of anti-IgG antibodies in human sera by radioimmunossay (RIA). J Immunol Methods 29:43–56

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

About this article

Cite this article

Jonsson, T., Arnason, J.A. & Valdimarsson, H. Enzyme-linked immunosorbent assay (ELISA) screening test for detection of rheumatoid factor. Rheumatol Int 6, 199–204 (1986). https://doi.org/10.1007/BF00541367

Download citation

  • Received:

  • Accepted:

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF00541367

Key words

Navigation