Table 2.

Interobserver and intraobserver reliability for measurement of passive knee range of movement.

Knee PROMInterobserver AgreementSEMIntraobserver AgreementSEM
ICC (95% CI)Mean Difference (95% CI)95% LoA (°)ICC (95% CI) MeanDifference (95% CI)95% LoA (°)
Flexion0.97 (0.92–0.99)−2.24 (−4.36 to −0.12)−12.29, 7.811.030.99 (0.99–0.99)−0.14 (−0.43 to 0.70)−5.37, 5.100.28
Extension0.87 (0.72–0.94)−1.00 (−2.55 to 0.55)−8.38, 6.380.750.96 (0.94–0.98)−0.17 (−0.61 to 0.27)−4.23, 3.890.22
  • ICC: intraclass correlation coefficient; PROM: passive range of movement; LoA: limits of agreement; SEM: standard error of measurement.