Table 1.

Sequence variables of the CRMO-adapted WB-MRI protocol.

Description OrientationT1-w TSE CoronalT2-w STIR SPACE CoronalT1-w TSE SagittalT2-w STIR SPACE Sagittal
TR, ms78340007006000
TI, ms210210
TE, ms123261148
Matrix, phase × read384 × 307320 × 259448 × 358384 × 326
Resolution, mm3, phase × read × slice1.1 × 1.1 × 5.01.5 × 1.5 × 5.01.1 × 0.9 × 3.51.2 × 1.0 × 3.5
FOV, mm2480 × 336480 × 336400 × 400400 × 400
Flip angle, °180T2 var180180
Bandwidth, Hz/px1611116180250
Parallel imaging methodGRAPPAGRAPPAGRAPPAGRAPPA
Acquisition time, s106 × 5 (6)*88 × 681 × 2155 × 2
  • * Dependent on body size. CRMO: chronic recurrent multifocal osteomyelitis; WB-MRI: whole-body magnetic resonance imaging; TSE: turbo spin-echo; STIR: short-tau inversion recovery; SPACE: sampling perfection with application optimized contrasts using different flip angle evolution; TR: time of repetition; TI: inversion time; TE: echo time; FOV: field of view; GRAPPA: generalized autocalibrating partially parallel acquisitions.